Run Time Error (RTE) 70 - permission denied

 

Run Time Error 70 is a sharing violation error. With Archive this indicates that the activity you are trying to perform should only be done if no one else is using the system, but at this time there are other users.

 

 

 

To overcome problem

 

 

All other users exit program

Make sure all other users of the program have closed down out of the Private Funds Manager. Then try archiving again.

 

 

 

Stand-alone installations

If you are the only user of the Private Funds Manager, then the error usually indicates that the program was previously closed down incorrectly or experienced a problem during close down. This leaves a locking file called PFM5.LDB on the system, which then causes the RTE 70.  

 

Close down Private Funds Manager. Using Windows Explorer or My Computer, navigate to the Private Funds Manager folder and delete the file called PFM5.LDB – Microsoft Access Record-Locking Information File (be very careful not to delete PFM5.MDB as this is your database!)

 